home page > products

fire alarm and smoke detection


AFS42 fire alarm system

AFS42 fire alarm system is addressable, one-loop, can have up to 100 addresses in a loop and makes it possible to create a modern fire alarm system in small and medium buildings. The system identifies the place where the fire breaks out and automatically turns on independently programmed executing devices. In order to get more lines and outputs for executing devices it is possible to connect up to five AFS42 central systems into one net. AFS42 makes it possible to run conventional line devices. Dla uzyskania większej ilości linii i wyjść dla urządzeń wykonawczych można połączyć do pięciu central AFS42 w sieć. Umożliwia obsługę konwencjonalnych urządzeń liniowych. It complies with the safety requirements of PN-EN 54 norm.

 


 

 

Price from: 1690.00 zł

more

ASW45 autonomic controller of executing devices

The controller ASW45 is destined to set working (by no-potential contacts of the relay) executing devices – the elements of the fire alarm systems – such as fans, signaling device, smoke flaps. The executing devices are set working by the module after a detection of smoke by OSD23/03 detectors. They are stopped after 40 s – 1.5 min from the moment at which the detector stopped signalizing the presence of smoke.

Price from: 44.00 zł

more

GNA42 base

The base is intended for mounting and addressing OSD23 optical smoke detectors in AFS42 system. Mechanically it is identical with GNP18 base – additionally it has installed MAR42 module. Apart from addressing line elements it is also a two-sided short-circuit insulator. It complies with the safety requirements and it can be used in fire alarm systems.

Price from: 83.00 zł

more

GNP18 base for optical smoke detectors

The base enables the OSD23 detector to be connected to a conventional line of fire alarm systems. It also enables the connection of the alarm output signal.

Price from: 11.00 zł

more

GNW12 base for optical smoke detectors

The base enables the OSD23 detector to be connected to any alarm system. It is equipped with two supply connectors, two micro-switch connectors, three alarm transmitter's connectors and a NC/NO switch. The base is available in three versions: GNW12 – supply voltage 12V; GNW12-24 – supply voltage 24V; GNW12-AR – automatically resets the detector when the smoke ceases.

Price from: 18.00 zł

more

KLP47 converter of fire line into alarm line

The KLP47 converter of a fire detection systems line into a burglar alarm systems line enables the connection of a standard, two-lead line with fire detectors to a six-lead fire line of a burglar alarm system.

 

Price from: 39.00 zł

more

OSD23 optical smoke detector

The smoke sensor is designed to detect presence of smoke in the air during the beginning of the fire. Przydatność pożarowa: TF1(C), TF2(A), TF3(A), TF4(B), TF5(B). There is a possibility to connect it either to fire detection systems or to alarm systems.Operating voltage - from 12 to 28V. The detector is available in three versions: OSD23M – operational state signalled by a flashing LED; OSD23R – automatic cancellation of the alarm after the smoke ceases; OSD23MR – both of the two functions mentioned above. The detector has EC certificate of conformity.

 

Price from: 72.50 zł

more

ROP42 addressing manual alarm call point

ROP42 is intended to work in AFS42 system. Breaking the glass raises the alarm. It can be mounted inside buildings. As an element of the system it is addressable and is equipped with two-sided short-circuit insulator. It complies with the safety requirements of PN-EN 54-11 norm.

Price from: 135.00 zł

more